Biodiesel Testing (B100 / FAME) Based on E.SDM Kemen No. 257.K / EK01 / MEME.E / 2026

Ensure Biodiesel Mutu (B100 / FAME) As Default Program B50

Biodiesel or Fatty Acid Methyl Esther (FAME / B100) It's a biofuel that's produced from tablati oil through the transsesterification process and used as mixed components (blendstock) In diesel fuel. Along with the implementation of the mandatori program B50, the government established that the biodiesel that will be put into solar oil should meet certain quality specifications before the blending process is done.

Through The decree of ESDM Minister number 257.K / EK.01 / ME.E / 2026The government sets the standard and quality of Biodiesel (B100 / FAME) as a raw B50 mixing material.

PT Hidea Core provides service Biodiesel Testing (B100 / FAME) to help biometric producers, blending terminals, distributors, and industrial users to do quality control according to the current regulation.


Biodiesel Testing Parameters (B100 / FAME)

According to ESM Kemmen No. 257.K / EK.01 / ME.E / 2026, the Biodiesel testing (B100 / FAME) includes 24 main parameters that are grouped as follows.

Physical characteristic

Physical parameters are used to evaluate the basic properties of biodiesel during storage, distribution and mixing.

ParameterRace Method
Density at 15 ° CASTM D1298 / ASTM D4052
Kinematic Vistoity at 40 ° CASTM D445
Flash PointASTM D93
TemperatureASTM D1160
Cold Filter Plugging Point (CFPP)ASTM D6371
ColourASTM D1500

The parameters affect the ability of alir, the process of fuel atomization, storage security, and performance when used as a solar alloy component.


Chemical characteristic

Chemical characteristics are used to ensure biodiesel has good stability and doesn't cause problems during storage or use.

Analysed parameters include:

  • Cetane Number
  • Sulfur
  • Phosphorus
  • Acid Number
  • Esther Content
  • Iodine Number
  • Oxygen Stability
  • Monoglycerade
  • Free Glycerol
  • Total Glycerol

The parameters are crucial to maintaining the quality of burning, stability of oxidation, and biodiesel compatibility with modern fuel systems.


Contaminan Dept

Contaminan can affect the age of equipment, injection systems, and fuel quality. Therefore, regulation also sets the testing against:

  • Water Content
  • Sulfated Ash
  • Carbon Residue
  • Copper Strip Corrosion
  • Sodium + Potassium (Na + K)
  • Calcium + Magnesium (Ca + Mg)
  • Total Contamination
  • Cleaniness

This control parameters help minimize the formation of deposits, corrosion, and blockage of fuel systems.


Testing Method

Biodiesel testing (B100 / FAME) is used using methods that are required in ESERM Kemen and referring to international standards such as ASTM, EN, AOCS and SNI.

Some testing methods are generally used amongst others:

ParameterMethod
DensityASTM D1298 / ASTM D4052
Kinematic VistolityASTM D445
Flash PointASTM D93
SulfurASTM D5453
Acid NumberASTM D664
Water ContentASTM D6304
CFPPASTM D6371
Carbon ResidueASTM D4530
Total ContaminationASTM D6217
CleaninessASTM D7619

The selection of methods is done according to the analysed parameters so the test results have adequate accuracy and search.


Test Peak

Biodiesel Testing Service (B100 / FAME) includes:

  • Consultation needs testing.
  • Acceptance or sample retrieval.
  • Lab analysis according to requested parameters.
  • Verification and validation of results.
  • Publishing the test results report.

The entire process is done according to laboratory procedures to ensure that the results are representational and accountable.


Biodiesel Testing Applications (B100 / FAME)

Biodiesel testing (B100 / FAME) required by various parties, among other things:

  • Biodiesel producers.
  • Terminal blending fuel.
  • Fuel distributor.
  • palm oil industry.
  • The refinery and storage facility.
  • Quality control lab.
  • Power companies and power plants.

Testing is done as part of quality control before biodiesel is used as a raw alloy with solar oil.


Why is the Biodiesel Testing Important?

Lab testing provides all sorts of benefits, among them:

  • Make sure the Biodiesel spec is compatible (B100 / FAME) before the blending process.
  • Support quality control during production.
  • Reduce the risk of discrepancy in the end product of the B50.
  • Support compliance against government regulations.
  • Provides technical data that can be used for product quality evaluations.

Why choose PT Hidea Core?

PT Hidea Core provides biodiesel testing services with laboratory approaches that focus on the quality of data and industrial needs.

Our service's excellence includes:

  • Testing uses a standard appropriate method.
  • A competent lab personnel.
  • Lab control.
  • The test results report are clear and understandable.
  • Technical consulting support to suit the customers.

Service Information

PT Hidea Core provides service Biodiesel Testing (B100 / FAME) For various industrial needs.

Available parameters include:

  • Density
  • Kinematic Vistolity
  • Cetane Number
  • Flash Point
  • Copper Strip Corrosion
  • Carbon Residue
  • System
  • Sulfur
  • Phosphorus
  • Acid Number
  • Free Glycerol
  • Total Glycerol
  • Esther Content
  • Iodine Number
  • Oxygen Stability
  • Monoglycerade
  • Water Content
  • Cold Filter Plugging Point (CFPP)
  • Sodium + Potassium
  • Calcium + Magnesium
  • Total Contamination
  • Cleaniness

For technical consulting or biodiesel testing requirements (B100 / FAME), please contact:

Custom Service PT Hidea Core
📞 +62 877-6494-5736

Pata Safira Nur
Pata Safira Nur
Articles: 23

Leave a reply

Your email address will not be public. Required fields are marked *