Cold Finger Test Analysis for Wax Deposition and Paraffin Inhibitor Evaluation
The integrity of the quality of products, operational efficiency, and efficacy of production is an important aspect of the oil and gas industry. One of the problems often faced in production and oil transportation is the creation of sediment. wax or paraffin that can inhibit fluid flow in the pipe system.
PT Hidea Core Service provides Cold Finger Test Services to support a formation evaluation wax deposition And chemical effectiveness testing. paraffin inhibitor on an oil sample. This test was done by evaluating the amount of deposit wax formed on the surface of low berahu in a controlled state of testing.
Through Cold Finger analysis, the company can obtain lab data to compare the characteristics of wax forming on samples without treatment and samples given to chemical inhibitors. The test results can be one of the basics in evaluating chemical product performance for oil & gas industry needs.
Cold Finger Test expert for Oil & Gas Industries
For companies of migas operators, producers, distributors, and chemical suppliers, Cold Finger testing has an important role in evaluating the potential deposit wax forms and performance of paraffin control products. Some of the major benefits of this testing include:
- Wax Deposition Formation Evaluation
Identifying the proclivities of the subtlety wax on the surface are low-heeled through simulation lab testing conditions. - Test Effective Paraffin Inhibitors
Evaluate the chemical abilities of inhibitors in reducing deposit wax formation by comparing the results of sample testing without treatment and samples given inhibitors. - Chemical Concentrate Optimize
Compare the performance of inhibitors in some concentration variation to obtain information about doses that provide the best prevention results in the testing conditions. - Chemical Product Development Support
Provides test data that producers and chemical suppliers can exploit in the formulation evaluation and product development process oilfield chemicals. - Flow Assurance Evaluation Supporter
Giving information about the propensity for the formation of wax relevant to evaluation the problem of the oil flow in the production and transportation system.
Cold Finger Test Technical Specification
Cold Finger Test is a test method used to evaluate the formation of deposit wax on the metal surface that is cooled and placed in petroleum samples.
In the process of testing, oil samples are maintained at certain temperatures, then Cold Finger surfaces are guarded at lower temperatures. The discrepancy of the temperature creates conditions that allow the wax component to be detected on the surface of the device.
Here are the technical parameters that are generally observed in the implementation of Cold Finger testing:
| Testing Parameters | Technical Description |
|---|---|
| Sample Type | Crude Oil and the petroleum samples that have the potential to form wax. |
| Bulk Oil Temperature | Temperature of oil samples during testing |
| Cold Finger Temperature | Metal surface temperature where deposit wax is formed |
| Temperature Gradient | The temperature difference between an oil sample and a Cold Finger surface |
| Stirring Speed | Fade speed during testing |
| Test Duration | Long time testing to evaluate deposit formation |
| Inhibitors Concentrate | The concentration of paraffin inhibitors added to the sample |
| Wax Deposit Weight | The weight of deposit wax formed on the surface of Cold Finger |
Temperature conditions, fusion speed, testing duration, and surface characteristics the device needs to be controlled so that the test results can be compared consistently. Operational parameter values are determined by test procedures and analysed sample characteristics.
Cold Finger Analysis Scope
Cold Finger Test services can be used to support various needs for chemical evaluation and the characteristics of petroleum in the Oil & Gas sector, among other things:
- Wax Deposition Analysis - Evaluate the number of deposit wax that formed on Cold Finger's surface during the testing process.
- Paraffin Inhibitor Performance Test - Evaluating chemical effectiveness paraffin inhibitors in reducing deposit wax formation.
- Inhibitors Concentrate Evaluation - Compare the performance inhibitors on some concentration variations to know the dose effect on deposit formation.
- Chemical Product Screen - Support the screening process and the performance comparison of some chemical products intended for wax control.
- Wax Inhibitory Efficiency - Calculates the efficiency of barrier wax based on heavy ratio of deposit on samples without inhibitors and samples with inhibitors added.
One of the evaluation parameters that can be used is Wax Inhibitory Effective (WIE), that's the percentage of deposit wax reduction after adding inhibitors compared to untreated samples.
In general, calculations can be stated as follows:
Wax Inhibitory Efficiency (%) = [(W]
Description:
- W = The heavy deposit wax on the sample without adding inhibitors (blank).
- W = Heavy deposit wax on samples with inhibitors added (treated sample).
The bigger the deposit reduction percentage, the higher the effectiveness of the barrier wax is shown in that testing condition. A fixed result interpretation needs to consider the characteristic of the sample and test conditions used.
Cold Finger Test PT Hidea Core Analysis
As the lab focuses on the testing service of the Oil & Gas sector, PT Hidea Core Supports the need for petroleum analysis and chemical evaluation through laboratory testing services adjusted to industrial needs.
Cold Finger Analyzer Service can be one of the product evaluation supporters. paraffin inhibitor For manufacturer companies, distributors, and chemical suppliers who need product performance data on the formation of wax in petroleum samples.
For more information on Cold Finger Test Analysis, technical consulting, or price bidding, please contact our team:
PT Hidea Core
Technological Area and Tekno Park, Block J1. 18, BSD, South Attack, Banten 15312
Email: labservices@hidea.id
WhatsApp: + 62 877-6494-5736
High Idoas. Solution.